1200°C Rotary Tube Furnace
Model | SH-FU-120RTG-2
|
---|---|
Max Temp | 1200℃ (2192℉)
|
Temp Controller | Programmable Controller(SP590)
|
Sensor
|
K type
|
Dimension Hot Zone
|
300 mm x 2 Hot Zone=Length 600 mm
|
Applicable Tube Diameter & length
|
120 Φ x 1500 mm
|
Dimension External
(W×D×H) |
2025x530x1545mm 79.72x20.86x60.82'' |
Heater Capa
|
5kW
|
Heating Jacking (option)
|
Max 400℃
|
Feeding Vessel
|
2L(Stainless Steel)
|
Receiving Vessel
|
2L(Stainless Steel)
|
Tube Rotation Speed
|
0.7 ~ 14 RPM
|
Feeder speed
|
0.5 ~ 10 RPM
|
Tube Angle
|
0 ~ 15˚
|
Heater Element
|
Kanthal A-1
|
Insulation
|
Ceramic Board & Wool
|
Gas port
|
¼” tube Lock valve
|
Gas Exhaust port
|
KF25 with Ball valve
|
Electrical Requirements
220V ,50/60Hz, 1ΦGas Exhaust port |
22.7 A
|
Mass Flow Controller(Multi gas selectable)
Model | MC Series | MCS Series | MCSS Series | MCV Series |
---|---|---|---|---|
Type | General | For Toxi Gas | For Toxi Gas(Includes CL2, SO2, HCl)
|
For Vacuum |
Flow Range | 0 ~ 1 slpm / 0 ~ 5 slpm | |||
Mass Flow Accuracy at
calibration conditions |
±0.6% of reading or ±0.1% of full scale | ±0.8% of reading or ±0.2% of full scale | ||
Operating Temperature Range | -10 to +60°C | |||
Temperature Accuracy | ±0.75°C | |||
Operating Pressure full scale | 145 PSIG | |||
Pressure Accuracy | Above 1 atm: ±0.5% of reading | |||
Typical Indication Response Time | < 10 ms | < 100 ms | ||
Typical Warm-Up Time | <1 Second | |||
Monochrome LCD | Simultaneously displays
mass Flow, pressure and temperature |
Simultaneously displays mass Flow,
Volumetric Flow, pressure and temperature | ||
Mechanical Dimensions
(HxWxD) |
104.14x91.44x27.94mm / 4.1x3.6x1.1" | 121.92x172.72x38.1mm /4.8x6.8x1.5" | ||
Gas Selectable | 98 Gas | 128 Gas (Cl2, SO2, HCl 제외) | 131 Gas (Cl2, SO2, HCl 포함) | 98 Gas |
Communication | RS-232 |
Mass Flow Controller(Multi gas selectable)
Model | BPR Series | BPRV Series | BPRS Series | BPRSS Series |
---|---|---|---|---|
Type | General | For Vacuum
|
For Toxi GasFor Toxi Gas
(Excluding CL2, HCl, SO2) |
For Toxi Gas
(Includes CL2, HCl, SO2) |
Pressure Range | 1PSIG ~ 15PSIG | 0PSIG ~ 1PSIG(0 ~ 760torr) | 1PSIG ~ 15PSIG | |
Standard Accuracy | ± 0.25% (≥ 1 psi) | |||
Repeatability | ± 0.08% Full Scale | |||
Typical Response Time | < 100 ms | |||
Warm-up Time | < 1 Second | |||
Operating Temperature | -10 to +60℃ | |||
Monochrome LCD | Displays Pressure | |||
Mechanical Dimensions
(HxWxD) |
104.14x91.4x27.94mm / 4.1x3.6x1.1" | |||
Communication | RS-232 |
SH Scientific is 40 years old laboratory equipment manufacturer and we supply vacuum ovens, cold trap baths, vacuum pumps, industrial drying ovens, forced convection drying ovens,
CBD isolate vacuum chambers, terpene traps, stirring mantles, recirculating chillers and heaters, incubators, climate chambers, bio safety cabinets, fume hoods, autoclaves, water baths,
oil baths, ultrasonic cleaners, rotary evaporators, glass reactors, clean bench and so on.
And we do OEM and custom products as well.
Product related questions and answers
There are no posts to show